Table 3: Ranges for Channelized E1 Configuration
RangeOptionItem
0 through 7
(see note below)
slot-numberFPC slot
0 through 3pic-numberPIC slot
0 through 9link-numberE1 link
0 through 23group-numberDS0 channel group
0 through 31 (with time slot 0 reserved)
(see note below)
time-slot-rangeTime slot
The theoretical maximum number of channel groups possible per PIC is 10 * 24 = 240.
This is within the maximum bandwidth available.
NOTE: NxDS0 time slots configured on either a channelized STM1 IQ or IQE
interface or channelized E1 IQ or IQE interface are numbered from 1 to 31 (0
is reserved), while fractional E1 time slots range from 2 to 32 (1 is reserved).
The FPC slot range depends on the router. For a routing matrix, the range is
from 0 through 31. For M40, M40e, M160, M320, M120, and other T Series
routers, the range is from 0 through 7. For M20 routers, the range is from 0
through 3. For M10 and M10i routers, the range is from 0 through 1. For M5
and M7i routers, the only applicable value is 0.
Configuring Channelized E1 Interface Properties
To configure channelized E1 interface properties, include the e1-options statement at the
[edit interfaces interface-name] hierarchy level:
[edit interfaces interface-name]
e1-options {
fcs (16 | 32);
framing (g704 | g704-no-crc4 | unframed);
idle-cycle-flag (flags | ones);
loopback (local | remote);
start-end-flag (filler | shared);
}
To specify options for each of the DS0 channels, include the ds0-options statement at
the [edit interfaces interface-name] hierarchy level:
[edit interfaces interface-name]
ds0-options {
byte-encoding (nx56 | nx64);
fcs (16 | 32);
idle-cycle-flag (flags | ones);
Copyright © 2014, Juniper Networks, Inc.10