MX2810
M13 Multiplexer
User Manual
Manual P/N 61185001L1-1C
CD P/N 32536153@A
61185001L1-1C
April 2003
4185001L1 MX2810 Chassis with two PSUs and two DS3 Controllers
4185001L2 MX2810 Chassis with two PSUs and one DS3 Controller
4185001L3 MX2810 Chassis with one PSU and two DS3 Controllers
4185001L4 MX2810 Chassis with one PSU and one DS3 Controller
1200287L1 Amp to Punch-Down Cable 25 ft.
1200287L5 Amp to Punch-Down Cable 50 ft.
1200287L7 Amp to Punch-Down Cable 100 ft.
1200291L1 Breakout Panel
1200291L5 BNC Patch Panel
Zobrazit stránku 0
1 2 3 4 5 6 ... 203 204

Shrnutí obsahu

Strany 1 - User Manual

MX2810M13 Multiplexer User ManualManual P/N 61185001L1-1CCD P/N 32536153@A61185001L1-1CApril 20034185001L1 MX2810 Chassis with two PSUs and two DS3 Co

Strany 2 - Trademark Information

Table of Contentsx MX2810 M13 User Manual 61185001L1-1DS2 Statistics...

Strany 3 - Service Type REN FIC USOC

Chapter 6. Loopbacks6-4 MX2810 M13 User Manual 61185001L1-1Figure 6-5. Digital Line/Network LoopbackCodec Line/NetA CODEC LINE/NET loopback performs

Strany 4

Chapter 6. Loopbacks61185001L1-1 MX2810 M13 User Manual 6-5CSU LoopbackA CSU LOOPBACK enables the MX2810 to generate a CSU loop up pattern (001001…) t

Strany 5

Chapter 6. Loopbacks6-6 MX2810 M13 User Manual 61185001L1-1Figure 6-7. Loopback Menu with BERT SelectedLine BERTA LINE BERT enables the MX2810 to per

Strany 6 - Warranty and Customer Service

Chapter 6. Loopbacks61185001L1-1 MX2810 M13 User Manual 6-7DS3 LOOPBACKSAfter you select DS3 LOOPBACK, the menu in Figure 6-8 appears. The sections fo

Strany 7

Chapter 6. Loopbacks6-8 MX2810 M13 User Manual 61185001L1-1Figure 6-9. Line Loopback TestDigital LoopbackA DIGITAL LOOPBACK loops the entire DS3 back

Strany 8

Chapter 6. Loopbacks61185001L1-1 MX2810 M13 User Manual 6-9Figure 6-11. Network Loopback TestRemote LoopbackA REMOTE LOOPBACK performs a loopback on

Strany 9

Chapter 6. Loopbacks6-10 MX2810 M13 User Manual 61185001L1-1Figure 6-12. DS2 Loopback MenuDS2 NetworkA DS2 NETWORK loopback test loops the selected D

Strany 10 - Table of Contents

61185001L1-1 MX2810 M13 User Manual 7-1Chapter 7Circuit RedundancyThe MX2810 provides backup measures of protection for circuit failure. The followin

Strany 11

Chapter 7. Circuit Redundancy7-2 MX2810 M13 User Manual 61185001L1-1NON-REDUNDANT MODEIn Non-Redundant Mode, the MX2810 houses only one controller car

Strany 12

Chapter 7. Circuit Redundancy61185001L1-1 MX2810 M13 User Manual 7-3CIRCUIT FAILURE RECOVERY MODEIn Circuit Failure Recovery Mode, two controller card

Strany 13 - List of Figures

Table of Contents61185001L1-1 MX2810 M13 User Manual xiTL1 Messages ...

Strany 14

Chapter 7. Circuit Redundancy7-4 MX2810 M13 User Manual 61185001L1-1Table 7-1. Configuration Requirements for Circuit RecoverySelection Path Recommen

Strany 15 - List of Tables

61185001L1-1 MX2810 M13 User Manual 8-1Chapter 8Power Loss RecoveryThe MX2810 provides backup measures of protection for both power supply and power s

Strany 16

Chapter 8. Power Loss Recovery8-2 MX2810 M13 User Manual 61185001L1-1NON-REDUNDANT POWER MODEIn Non-Redundant Power Mode, the MX2810 houses only one p

Strany 17 - Introduction

Chapter 8. Power Loss Recovery61185001L1-1 MX2810 M13 User Manual 8-3POWER SUPPLY RECOVERY MODEIn Power Supply Recovery Mode, two power supply cards a

Strany 18 - T3 OVERVIEW

Chapter 8. Power Loss Recovery8-4 MX2810 M13 User Manual 61185001L1-1POWER SUPPLY AND SOURCE RECOVERY MODEIn this mode, two power supply cards are ins

Strany 19 - Chapter 1. Introduction

Chapter 8. Power Loss Recovery61185001L1-1 MX2810 M13 User Manual 8-5BATTERY BACKUP MODEWith the installation of the ADTRAN Power Supply/Battery Charg

Strany 20 - AVAILABLE OPTIONS

Chapter 8. Power Loss Recovery8-6 MX2810 M13 User Manual 61185001L1-1

Strany 21

61185001L1-1 MX2810 M13 User Manual 9-1Chapter 9Transaction Language 1 (TL1)INTRODUCTIONTransaction Language 1 (TL1) is a BELLCORE standard used in th

Strany 22

Chapter 9. Transaction Language 1 (TL1)9-2 MX2810 M13 User Manual 61185001L1-1• 1-way in or 2-way operation•Up to four SVCs• Up to 64 Kbps (synchronou

Strany 23 - Installation and Operation

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-3An account may be setup via the VT100 menus (Configuration/System Manage

Strany 24 - Power Up

Table of Contentsxii MX2810 M13 User Manual 61185001L1-1

Strany 25 - Power Requirements

Chapter 9. Transaction Language 1 (TL1)9-4 MX2810 M13 User Manual 61185001L1-1To bring up a TL1 TELNET connection (up to eight may be active,) a TELNE

Strany 26

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-5<ctag> is the Correlation Tag, a 1 to 6 character alphanumeric ide

Strany 27 - Connecting the Breakout Panel

Chapter 9. Transaction Language 1 (TL1)9-6 MX2810 M13 User Manual 61185001L1-1Acknowledgment MessagesAcknowledgment messages are brief output messages

Strany 28 - Front View

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-7<date> is the date in the form YY-MM-DD,<time> is the time i

Strany 29

Chapter 9. Transaction Language 1 (TL1)9-8 MX2810 M13 User Manual 61185001L1-1The MX2810 specifically uses “quoted line(s)” in the response message of

Strany 30 - Power Connection

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-9Possible values for the ALARM CODE field include:• *C - Critical Alarm•*

Strany 31 - LED Descriptions

Chapter 9. Transaction Language 1 (TL1)9-10 MX2810 M13 User Manual 61185001L1-1the time in HH-MM-SS format, and whether the alarm is NEND of FEND (&qu

Strany 32

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-11For possible CONDTYPE codes for both REPT-ALM and REPT-EVT quoted lines

Strany 33

Chapter 9. Transaction Language 1 (TL1)9-12 MX2810 M13 User Manual 61185001L1-1MOD2 Specifies what entity type to allow:EQPT... General Equipment Unit

Strany 34

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-13TID* Target IDAID UsernameCTAG* Transaction Number (integer)PARAM1 User

Strany 35 - Craft Port

61185001L1-1 MX2810 M13 User Manual xiiiList of FiguresFigure 1-1. E1 Patch Panel...

Strany 36

Chapter 9. Transaction Language 1 (TL1)9-14 MX2810 M13 User Manual 61185001L1-1RTRV-HDR;Description Replies with a normal "COMPLD" responseT

Strany 37

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-15AID* Identifies the component to which the desired alarm pertains. Iden

Strany 38

Chapter 9. Transaction Language 1 (TL1)9-16 MX2810 M13 User Manual 61185001L1-1RTRV-COND-{EQPT|rr|ALL};Description Retrieves the requested alarms and

Strany 39 - Configuration

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-17TL1 Autonomous MessagesAutonomous messages provide a mechanism for real

Strany 40 - Chapter 3. Configuration

Chapter 9. Transaction Language 1 (TL1)9-18 MX2810 M13 User Manual 61185001L1-1An example of this command that would enable "all" autonomous

Strany 41 - DS3 Configuration

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-19;Where "Unit 1" is the <tid> defined in the menus,"

Strany 42

Chapter 9. Transaction Language 1 (TL1)9-20 MX2810 M13 User Manual 61185001L1-1REPT ALMT3301 MN TSA SA NEND DS3 In-test301 MN EXT-DS3 SA FENDFEND DS3

Strany 43 - DS2 Configuration

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-21REPT ALMT3302 (Ctrl A) CR LOS SA NEND DS3 Loss Of Signal303 (Ctrl B)302

Strany 44 - T1/E1 State

Chapter 9. Transaction Language 1 (TL1)9-22 MX2810 M13 User Manual 61185001L1-1REPT-EVT indicates an informational event. Table 9-5 lists possible aut

Strany 45

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-23TL1 ERROR CODESWhen the MX2810 denies a received TL1 command, the Outpu

Strany 46 - T1/E1 Line Length

List of Figuresxiv MX2810 M13 User Manual 61185001L1-1Figure 5-4. DS3 24-Hour Alarm History Screen...

Strany 47 - T1/E1 Loopback Detection

Chapter 9. Transaction Language 1 (TL1)9-24 MX2810 M13 User Manual 61185001L1-1• <keyword> is one of the entries from the following data diction

Strany 48 - T1/E1 Line Identification

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-25TL1 RTRV examples:RTRV-T1::100:1; (this would return all common parame

Strany 49 - XCV Threshold

Chapter 9. Transaction Language 1 (TL1)9-26 MX2810 M13 User Manual 61185001L1-1 Table 9-7. TL1 Editing Data Dictionary for DS3Keyword Type Domain Des

Strany 50 - Management Options

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-27DS3MAXNUMSW INT 0, 1, 2, ..., N Maximum number of times per hour the un

Strany 51 - Alarm Relays

Chapter 9. Transaction Language 1 (TL1)9-28 MX2810 M13 User Manual 61185001L1-1The following data dictionary (Table 9-8) contains entries that are use

Strany 52

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-29The following data dictionary (Table 9-9) contains entries that are use

Strany 53

Chapter 9. Transaction Language 1 (TL1)9-30 MX2810 M13 User Manual 61185001L1-1Table 9-9. TL1 Editing Data Dictionary for DS1Keyword Type Domain Desc

Strany 54 - SNMP Management Options

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-31DSXLBKDETECTION ENUM One of the following:• DISABLE•CSU•NIU• UNAVAILIde

Strany 55

Chapter 9. Transaction Language 1 (TL1)9-32 MX2810 M13 User Manual 61185001L1-1The following data dictionary (Table 9-10) contains entries that are us

Strany 56

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-33PSPOWERFAILRLY Y/N Y or [N] Identifies status of Power Supply Power Fai

Strany 57

61185001L1-1 MX2810 M13 User Manual xvList of Tables Table 2-1. DC Connector Symbol Definitions...

Strany 58

Chapter 9. Transaction Language 1 (TL1)9-34 MX2810 M13 User Manual 61185001L1-1TL1 Loopback Commands:The OPR-LPBK and RLS-LPBK commands are provided a

Strany 59 - System Security

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-35Table 9-12. DS2 TL1 Loopback CommandsThe following table will describe

Strany 60

Chapter 9. Transaction Language 1 (TL1)9-36 MX2810 M13 User Manual 61185001L1-1

Strany 61

61185001L1-1 MX2810 M13 User Manual A-1Appendix AAcceptance Test ProcedureOVERVIEWThis document describes the procedures to be used in performing acce

Strany 62

Appendix A. Acceptance Test ProcedureA-2 MX2810 M13 User Manual 61185001L1-1• Alarm Verification• Redundancy/Protection Switching Tests• Configuring t

Strany 63 - Date & Time

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-3accepted, the MX2810 Main Menu should appear. This is the screen from whi

Strany 64

Appendix A. Acceptance Test ProcedureA-4 MX2810 M13 User Manual 61185001L1-1Miscellaneous• Loopback Time Out = 1 hr. (default) DS2 Configuration (no c

Strany 65 - ONFIGURATION

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-5menu and proceed to the next step. If not, perform the Set Multiple routi

Strany 66

Appendix A. Acceptance Test ProcedureA-6 MX2810 M13 User Manual 61185001L1-1OVERALL SYSTEM AND CABLING TESTNow that the system has been properly provi

Strany 67 - UTILITIES

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-75. The MX2810 will be in an alarm condition because of the previously tes

Strany 68 - Updating Software

List of Tablesxvi MX2810 M13 User Manual 61185001L1-1

Strany 69

Appendix A. Acceptance Test ProcedureA-8 MX2810 M13 User Manual 61185001L1-17. Leave this test set-up in place, as it will be used during the redunda

Strany 70

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-9ALARM VERIFICATIONThe MX2810 has three sets of alarm relay contacts availa

Strany 71 - Utilities

Appendix A. Acceptance Test ProcedureA-10 MX2810 M13 User Manual 61185001L1-1MAJOR and MINOR Alarm Relay TestThis test will actuate the MAJOR and MINO

Strany 72

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-11Power Supply RedundancyWhen installed, the MX2810 can be wired to have ei

Strany 73 - Resetting the System

Appendix A. Acceptance Test ProcedureA-12 MX2810 M13 User Manual 61185001L1-12. Go to the fuse panel at the top of the bay and remove the fuse corres

Strany 74

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-13the Controller, an alarm is initiated and the front panel LEDs reflect th

Strany 75 - Rx Framing

Appendix A. Acceptance Test ProcedureA-14 MX2810 M13 User Manual 61185001L1-12. From the System Management Configuration screen, select Local IP Addr

Strany 76 - Chapter 4. Status

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-15no settings on the MX2810. The RS232 Data Communication Interface on the

Strany 77

Appendix A. Acceptance Test ProcedureA-16 MX2810 M13 User Manual 61185001L1-1• Disabled – No signal continuity exists through the MX2810 and no alarms

Strany 78 - POWER SUPPLY STATE

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-17MX2810 ATP CHECKLIST/SIGN-OFFUse the table below to identify the MX2810 c

Strany 79 - SYSTEM STATE

61185001L1-1 MX2810 M13 User Manual 1-1Chapter 1IntroductionPRODUCT OVERVIEWThe MX2810 is an M13 multiplexer that consolidates T1 and E1 signals into

Strany 80 - Protection

Appendix A. Acceptance Test ProcedureA-18 MX2810 M13 User Manual 61185001L1-1

Strany 81 - T1/E1 STATE

61185001L1-1 MX2810 M13 User Manual B-1Appendix BPinoutsThe following tables give the pin assignments for the connectors located on the MX2810. For mo

Strany 82 - ACKNOWLEDGE ALARMS (ACO)

Appendix B. PinoutsB-2 MX2810 M13 User Manual 61185001L1-1Table B-2. LAN Port Pin AssignmentsPin Name Description1 TD+ The positive signal for the TD

Strany 83 - Statistics

Appendix B. Pinouts61185001L1-1 MX2810 M13 User Manual B-3Table B-3. Amp Pin AssignmentsPin Function Pin1 RING 1 TIP 1 332 RING 2 TIP 2 343 RING 3 TI

Strany 84 - DS3 Statistics

Appendix B. PinoutsB-4 MX2810 M13 User Manual 61185001L1-1

Strany 85 - Chapter 5. Statistics

61185001L1-1 MX2810 M13 User Manual C-1Appendix CSpecifications SummarySPECIFICATIONS AND FEATURESThis section describes the standard specifications a

Strany 86

Appendix C. Specifications SummaryC-2 MX2810 M13 User Manual 61185001L1-1Line loopbacksDS2 InterfacesDS2 network loopbacksDSX-1 InterfacesLocal and ne

Strany 87

Appendix C. Specifications Summary61185001L1-1 MX2810 M13 User Manual C-3EnvironmentOperating: 0 to 50 °C (32 to 122 °F)Storage: -20 to 70 °C (-4 to 1

Strany 88

Appendix C. Specifications SummaryC-4 MX2810 M13 User Manual 61185001L1-1

Strany 89

61185001L1-1 MX2810 M13 User Manual D-1Appendix DAcronyms/AbbreviationsACO ... alarm cut offACT... activeAIS...

Strany 90

Chapter 1. Introduction1-2 MX2810 M13 User Manual 61185001L1-1The major features of the MX2810 are as follows:• Built-in 1:1 redundancy• Hot-swappable

Strany 91 - DS2 Statistics

Appendix D. Acronyms/AbbreviationsD-2 MX2810 M13 User Manual 61185001L1-1CSES... C-bit severely errored secondsCSU ...

Strany 92

Appendix D. Acronyms/Abbreviations61185001L1-1 MX2810 M13 User Manual D-3LAIS ... loop side alarm indication signalLAN...

Strany 93 - T1/E1 Statistics

Appendix D. Acronyms/AbbreviationsD-4 MX2810 M13 User Manual 61185001L1-1PVC ... permanent virtual circuitRD... rec

Strany 94 - PROTECTION SWITCH STATISTICS

61185001L1-1 MX2810 M13 User Manual E-1Appendix EGlossary10BaseTEthernet connector which implements the IEEE standard on 24-gauge, unshielded twisted-

Strany 95

Appendix E. GlossaryE-2 MX2810 M13 User Manual 61185001L1-1bipolarA signal containing both positive and negative amplitude components.bipolar violatio

Strany 96

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-3C-bitAn overhead bit in the DS3 string not used for framing, parity, or alarm indica-tion.C

Strany 97 - Loopbacks

Appendix E. GlossaryE-4 MX2810 M13 User Manual 61185001L1-1craft portThe electrical interface between the MX2810 and the control terminal. The con-tro

Strany 98 - Tributary

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-5delayThe amount of time by which a signal is delayed. A round-trip transmission delay measu

Strany 99

Appendix E. GlossaryE-6 MX2810 M13 User Manual 61185001L1-1ethernet Transmission protocol for packet-switching LANs. facilitiesThe equipment used by c

Strany 100 - Remote Loopback

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-7LANLocal area network. A privately owned network that offers high-speed commu-nications cha

Strany 101 - CSU Loopback w/BERT

Chapter 1. Introduction61185001L1-1 MX2810 M13 User Manual 1-310BaseT local area network (LAN) port. The MX2810 supports the MIB-II standard, RFC 1213

Strany 102 - Line BERT

Appendix E. GlossaryE-8 MX2810 M13 User Manual 61185001L1-1NCNormally closed. Relay switch contacts that remain closed when inactive.near endThe unit

Strany 103 - DS3 LOOPBACKS

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-9red alarmUnframed all ones signal (keep alive signal). A red alarm is declared on detec-tio

Strany 104 - Network Loopback

Appendix E. GlossaryE-10 MX2810 M13 User Manual 61185001L1-1SRData set ready. A signal on the DTE interface that indicates if a connection exists and

Strany 105 - DS2 LOOPBACKS

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-11WANWide area network. A communications network serving geographically separate areas. A WA

Strany 106 - DS2 Network

Appendix E. GlossaryE-12 MX2810 M13 User Manual 61185001L1-1

Strany 107 - Circuit Redundancy

61185001L1-1 MX2810 M13 User Manual Index-1IndexNumerics10BaseT connection, location of 2-724 Hour Alarm HistoryDS2 Statistics menu 5-9DS3 Statistics

Strany 108 - NON-REDUNDANT MODE

IndexIndex-2 MX2810 M13 User Manual 61185001L1-1BERTCSU Loopback w/ 6-5Line 6-6Bipolar Violations 5-11blue alarmDS2 State 4-7network state 4-2Remote s

Strany 109 - CIRCUIT FAILURE RECOVERY MODE

Index61185001L1-1 MX2810 M13 User Manual Index-3DS2 State 4-7AIS 4-7LOF 4-7OK 4-7RAI 4-7DS2 Statistics menu 5-9DS3 Alarm Traps Far-end Active Cards 3-

Strany 110 - Chapter 7. Circuit Redundancy

IndexIndex-4 MX2810 M13 User Manual 61185001L1-1Interface menu, T1/E1 3-6Interval starting at:, Performance Parameters (DS3) 5-6IOX PROGRAM FAILURE 3-

Strany 111 - Power Loss Recovery

Index61185001L1-1 MX2810 M13 User Manual Index-5MIB II Standard Alarm Traps 3-20Authentication Failure 3-20Cold Start 3-20Link Down 3-20Link Up 3-20MI

Strany 112 - NON-REDUNDANT POWER MODE

Trademark InformationOpenView is a trademark of Hewlett-Packard Company.Spectrum is a registered trademark of Cabletron.901 Explorer BoulevardP.O. Box

Strany 113 - POWER SUPPLY RECOVERY MODE

Chapter 1. Introduction1-4 MX2810 M13 User Manual 61185001L1-1TL1Transaction Language 1 (TL1) is an ASCII based language that supports both command-re

Strany 114

IndexIndex-6 MX2810 M13 User Manual 61185001L1-1Power Supply Alarm Traps 3-17Card Removed 3-17Malfunction 3-17Power Low 3-17Temperature Critical 3-17T

Strany 115 - BATTERY BACKUP MODE

Index61185001L1-1 MX2810 M13 User Manual Index-7specifications, MX2800 C-1Stand By, Card A/Card B 4-6State menu (DS3 State) 4-2State menus, T1/E1 3-6S

Strany 116

IndexIndex-8 MX2810 M13 User Manual 61185001L1-1TL1 9-1alarm events 9-17autonomous messages 9-17, 9-22commands 9-11Editing 9-23error codes 9-23informa

Strany 119

Chapter 1. Introduction61185001L1-1 MX2810 M13 User Manual 1-5E1 Patch Panel (P/N 1200291L5)The optional E1 patch panel (see Figure 1-1) connects to t

Strany 120 - TL1 MESSAGES

Chapter 1. Introduction1-6 MX2810 M13 User Manual 61185001L1-1

Strany 121 - TL1 Responses

61185001L1-1 MX2810 M13 User Manual 2-1Chapter 2Installation and OperationUNPACK, INSPECT, POWER UPReceiving InspectionCarefully inspect the MX2810 fo

Strany 122

Chapter 2. Installation and Operation2-2 MX2810 M13 User Manual 61185001L1-1Power UpThe MX2810 is powered using a -48V DC power source. The rear pane

Strany 123

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-3Table 2-1. DC Connector Symbol DefinitionsPower RequirementsTable 2-2 pro

Strany 124

Chapter 2. Installation and Operation2-4 MX2810 M13 User Manual 61185001L1-1The following UL requirements must be met during installation of the MX281

Strany 125

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-5RACKMOUNT INSTALLATIONThe MX2810 can be mounted into a standard 19-inch or

Strany 126

Chapter 2. Installation and Operation2-6 MX2810 M13 User Manual 61185001L1-1.Figure 2-2. The Breakout PanelConnecting the E1 Patch PanelThe optional

Strany 127 - ALW-MSG-{EQPT

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-7equipment. Descriptions for these items follow the figure. Pin assignment

Strany 128 - CANC-USER;

61185001L1-1 MX2810 M13 User Manual iiiFCC regulations require that the following information be provided in this manual:1. This equipment complies wi

Strany 129 - INH-MSG-{EQPT

Chapter 2. Installation and Operation2-8 MX2810 M13 User Manual 61185001L1-1Critical, Major, and Minor Alarm ConnectorsConnectors for critical, major,

Strany 130 - RTRV-ALM-{EQPT

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-9FRONT PANELThe MX2810 front panel is shown in Figure 2-4. Descriptions of

Strany 131

Chapter 2. Installation and Operation2-10 MX2810 M13 User Manual 61185001L1-1active controller card or the controller card on standby. The following t

Strany 132 - RTRV-COND-{EQPT

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-11T1/E1 Status LEDsThese LEDs apply to each individual T1 or E1. Different

Strany 133 - TL1 Autonomous Messages

Chapter 2. Installation and Operation2-12 MX2810 M13 User Manual 61185001L1-1Table 2-5. T1/E1 LED ConditionsLED State T1/E1 ConditionActive Cardgreen

Strany 134

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-13Craft PortThe CRAFT port provides connection to a VT100 EIA-232 compatibl

Strany 135

Chapter 2. Installation and Operation2-14 MX2810 M13 User Manual 61185001L1-1 Figure 2-5. Terminal Main MenuNavigating Within the MenusNavigate withi

Strany 136

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-15The MX2810 MAIN menu consists of the following sections: StatusProvides i

Strany 137

Chapter 2. Installation and Operation2-16 MX2810 M13 User Manual 61185001L1-1

Strany 138

61185001L1-1 MX2810 M13 User Manual 3-1Chapter 3ConfigurationTo configure the MX2810, use a 10BaseT ethernet connection or a VT100 terminal. Figure 3-

Strany 139 - TL1 Editing

iv MX2810 M13 User Manual 61185001L1-1Federal Communications CommissionRadio Frequency Interference StatementThis equipment has been tested and found

Strany 140

Chapter 3. Configuration3-2 MX2810 M13 User Manual 61185001L1-1Figure 3-2. Configuration Menu Tree1. Network Interface2. T1/E1 Interface4. UtilitiesD

Strany 141

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-3NETWORK INTERFACESelect NETWORK INTERFACE to access the network configuration parameter

Strany 142

Chapter 3. Configuration3-4 MX2810 M13 User Manual 61185001L1-1Remote LoopbacksSelect FEAC/C-BIT to allow the MX2810 to respond to remote loopback req

Strany 143

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-5Protection ConfigurationThe MX2810 houses two controller cards for 1:1 protection again

Strany 144

Chapter 3. Configuration3-6 MX2810 M13 User Manual 61185001L1-1The fourth T1/E1 port of the selected group is not available in this mode. Any combinat

Strany 145

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-7Figure 3-5. T1/E1 State MenuSet MultipleUse SET MULTIPLE (see Figure 3-6 on page 3-7)

Strany 146

Chapter 3. Configuration3-8 MX2810 M13 User Manual 61185001L1-1T1/E1 Line CodingSet the line code for each individual T1/E1 interface to match the con

Strany 147

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-9Figure 3-8. T1/E1 Line Length MenuT1/E1 Loopback DetectionChoose which T1/E1 lines wil

Strany 148

Chapter 3. Configuration3-10 MX2810 M13 User Manual 61185001L1-1T1/E1 Circuit ProtectionT1/E1 Circuit Protection determines which circuit will be allo

Strany 149

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-11Figure 3-11. Line Identification MenuXCV ThresholdSet a limit on code violations (CVs

Strany 150

61185001L1-1 MX2810 M13 User Manual vCanadian Equipment LimitationsNotice: The Canadian Industry and Science Canada label identifies certified equip-

Strany 151

Chapter 3. Configuration3-12 MX2810 M13 User Manual 61185001L1-1SYSTEM MANAGEMENTConfigure the MX2810 for management through SNMP, TELNET, or a VT100

Strany 152

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-13Subnet MaskEnter the subnet mask of the MX2810. This address is available from your ne

Strany 153 - Acceptance Test Procedure

Chapter 3. Configuration3-14 MX2810 M13 User Manual 61185001L1-1DS3 AlarmsDS2 AlarmsSystem Alarms Alarm DescriptionRAI (Major) The unit is re

Strany 154

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-15T1/E1 Alarms Power Supply AlarmsT1/E1 alarms are cleared when the T1/E1 is dis

Strany 155

Chapter 3. Configuration3-16 MX2810 M13 User Manual 61185001L1-1SNMP Management OptionsTrap IP AddressesEnter up to five IP addresses of SNMP managers

Strany 156

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-17Power Supply Alarm Traps Trap If enabled, the unit issues a trap when...Card Removed t

Strany 157

Chapter 3. Configuration3-18 MX2810 M13 User Manual 61185001L1-1DS3 Alarm Traps (Near-End Active and Standby Cards) Trap If enabled, the unit issues a

Strany 158

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-19DS3 Alarm Traps (Far-End Active Cards)DS2 Alarm Traps Trap If enabled, the unit issues

Strany 159

Chapter 3. Configuration3-20 MX2810 M13 User Manual 61185001L1-1T1/E1 Alarm Traps MIB II Standard Alarm Traps Trap If enabled, the unit issues a trap

Strany 160

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-21Read Community NameEnter the authentication strings used for SNMP management. Match th

Strany 161

vi MX2810 M13 User Manual 61185001L1-1Warranty and Customer ServiceADTRAN will replace or repair this product within the warranty period if it does no

Strany 162

Chapter 3. Configuration3-22 MX2810 M13 User Manual 61185001L1-1AdminThe user may view and/or alter all menu items. Only a user with an Admin user ac

Strany 163

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-23Loopback timeout X X XDS2 #1-7 mode (T1 or E1) X X XConfiguration – T1/E1 Interface me

Strany 164

Chapter 3. Configuration3-24 MX2810 M13 User Manual 61185001L1-1Terminal timeout XIP security XIP hosts XDate XTime XCircuit Identification menu XSysl

Strany 165

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-25Terminal Time OutSet the amount of time the terminal or TELNET session remains inactiv

Strany 166

Chapter 3. Configuration3-26 MX2810 M13 User Manual 61185001L1-1Figure 3-15. Equipment Identification MenuUnit IDProvides a user-configurable text st

Strany 167

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-27Host IP AddressSpecifies the IP address of the external server that is running the Sys

Strany 168 - (TRAFFIC READINESS)

Chapter 3. Configuration3-28 MX2810 M13 User Manual 61185001L1-1Autoprogram CardsEnable this function to allow the controller cards to automatically u

Strany 169 - MX2810 ATP CHECKLIST/SIGN-OFF

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-29UTILITIESThe UTILITIES menu (see Figure 3-16) allows you to view MX2810 system informa

Strany 170

Chapter 3. Configuration3-30 MX2810 M13 User Manual 61185001L1-1Loading Default SettingsSelect LOAD DEFAULT SETTINGS from the UTILITIES menu. Once the

Strany 171 - Appendix B

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-31Update Via XMODEMUpdating the FLASH Software via XMODEM requires that a VT100 terminal

Strany 172 - Appendix B. Pinouts

61185001L1-1 MX2810 M13 User Manual viiTable of ContentsList of Figures ...

Strany 173 - DSX1/E1 Amp connectors

Chapter 3. Configuration3-32 MX2810 M13 User Manual 61185001L1-1select either IMMEDIATE RESET to immediately reset the system or SCHEDULE RESET TIME t

Strany 174

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-33 5. The system must be manually reset after downloading new software for the active c

Strany 175 - Specifications Summary

Chapter 3. Configuration3-34 MX2810 M13 User Manual 61185001L1-1Saving to a TFTP ServerTo save current configuration information to a TFTP server, fol

Strany 176

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-353. Select LOAD AND USE CONFIG.Resetting the SystemThe system must be manually reset af

Strany 177

Chapter 3. Configuration3-36 MX2810 M13 User Manual 61185001L1-1

Strany 178

61185001L1-1 MX2810 M13 User Manual 4-1Chapter 4StatusView MX2810 status information by selecting 1-STATUS from the MAIN menu (see Figure 4-1). The in

Strany 179 - Acronyms/Abbreviations

Chapter 4. Status4-2 MX2810 M13 User Manual 61185001L1-1StateDisplays the current condition of the network. Possible conditions are listed in the foll

Strany 180

Chapter 4. Status61185001L1-1 MX2810 M13 User Manual 4-3RemoteThis field indicates the current state of the remote MX2810. Possible conditions are giv

Strany 181

Chapter 4. Status4-4 MX2810 M13 User Manual 61185001L1-1POWER SUPPLY STATEThis field indicates which types of power supplies are installed (AC or DC)

Strany 182

Chapter 4. Status61185001L1-1 MX2810 M13 User Manual 4-5SYSTEM STATEThese fields display information regarding the two controller cards. The followi

Strany 183 - Glossary

Table of Contentsviii MX2810 M13 User Manual 61185001L1-1Power Connection...

Strany 184 - Appendix E. Glossary

Chapter 4. Status4-6 MX2810 M13 User Manual 61185001L1-1Card A/Card BThese fields display the current state of the two controller cards. Possible stat

Strany 185

Chapter 4. Status61185001L1-1 MX2810 M13 User Manual 4-7Card CommThis field displays the current state of the communication link between the two contr

Strany 186

Chapter 4. Status4-8 MX2810 M13 User Manual 61185001L1-1ACKNOWLEDGE ALARMS (ACO)This selection allows you to remotely turn off an active alarm. It is

Strany 187

61185001L1-1 MX2810 M13 User Manual 5-1Chapter 5StatisticsVIEWING STATISTICAL INFORMATIONSelect 2-STATISTICS from the MAIN menu to access STATISTICS m

Strany 188

Chapter 5. Statistics5-2 MX2810 M13 User Manual 61185001L1-1DS3 StatisticsThis menu provides submenus for alarm history and performance parameters (se

Strany 189

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-3The following alarm counts are provided in this menu: Condition DescriptionLOS Number of

Strany 190

Chapter 5. Statistics5-4 MX2810 M13 User Manual 61185001L1-1Figure 5-3. DS3 Current Alarm Count ScreenFigure 5-4. DS3 24-Hour Alarm History ScreenPe

Strany 191

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-524-hour history statistics screen, use the left and right arrow keys to scroll through al

Strany 192

Chapter 5. Statistics5-6 MX2810 M13 User Manual 61185001L1-1Figure 5-6. DS3 Performance Parameters (24 Hour History)Figure 5-7. DS3 Performance Para

Strany 193

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-7Errored Seconds-Line (ES-L)Number of seconds in which one or more CVs or one or more LOS

Strany 194

Table of Contents61185001L1-1 MX2810 M13 User Manual ixTerminal Time Out ...

Strany 195

Chapter 5. Statistics5-8 MX2810 M13 User Manual 61185001L1-1Severely Errored Seconds - C-Bit (SESCP-P)Number of seconds with 44 or more CCVs, one or

Strany 196

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-9DS2 Statistics24 Hour Alarm HistoryThe MX2810 keeps track of RAI, OOF, and AIS alarms for

Strany 197

Chapter 5. Statistics5-10 MX2810 M13 User Manual 61185001L1-1Performance ParametersThe performance parameters screen displays a count of parity bit er

Strany 198

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-11T1/E1 StatisticsThe MX2810 keeps track of LOSS OF SIGNAL ALARMS, LINE CODING VIOLATIONS,

Strany 199

Chapter 5. Statistics5-12 MX2810 M13 User Manual 61185001L1-1PROTECTION SWITCH STATISTICSThis menu provides statistics regarding protection switches.

Strany 200

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-13system configuration are saved to non-volatile memory. Both the alarm log and system co

Strany 201

Chapter 5. Statistics5-14 MX2810 M13 User Manual 61185001L1-1

Strany 202

61185001L1-1 MX2810 M13 User Manual 6-1Chapter 6LoopbacksThe LOOPBACK menu allows you to initiate loopback tests from the MX2810. Figure 6-1 shows the

Strany 203

Chapter 6. Loopbacks6-2 MX2810 M13 User Manual 61185001L1-1T1/E1 LOOPBACKSAfter you select the number that corresponds with the line you want to test,

Strany 204

Chapter 6. Loopbacks61185001L1-1 MX2810 M13 User Manual 6-3Figure 6-3. Tributary Loopback TestAnalog NetworkAn ANALOG NETWORK loopback test loops the